Protect functions
Protect functions can prolong the air conditioner’
s service life and provide more comfortable
airflow.
Delay-starting protection for the compressor
The compressor will restart working at least
3 minutes (5 minutes in heating mode) after
being turned off to keep the pressure balance of
the cooling system.
C
Note: There will be 1 minute for
the compressor to work after the
unit is electrified for the first time.
Defrosting
The outdoor heat exchanger may frost if the
outdoor temperature is low and humidity is high.
In this case, auto-defrosting has operated for
3-10 minutes. pause indicator will be on, indoor
and outdoor fan stop.
Heating overload protection
When the temperature of indoor pipe is too high,
air conditioner enters heating overload protection.
And indoor fan speed should be adjusted to
a higher gear automatically. Outdoor fan and
compressor may be stopped. When indoor
pipe temperature drops to a rated value, air
conditioner will exit heating overload protection.
Indoor fan motor resumes to the normal status.
Blowing residual heat function
Indoor fan will keep running at low fan speed for
80 seconds when air conditioner is stopped in
heating mode.
Cooling airflow proof
In the first several minutes of heating operation,
PAUSE indicator lights; indoor fan doesn’t run
and louver blades cannot be controlled. About
5 minutes later, air conditioner will blow heat
airflow, PAUSE indicator is off.
Freeze-prevention
To prevent indoor heat exchanger freezing
in cooling and dehumidification operation,
compressor or outdoor fan may stop running;
indoor fan speed will be adjusted to a higher gear
automatically.
Dry for enzyme-prevention
Indoor fan motor will go on running for 3 minutes
at low fan speed when turned off in cooling mode
in order to keep dry condition inside the unit.
Auto restart
The unit memories the operation mode, air flow
setting, temperature setting etc., so that should
there be a power failure when the unit is in
operation, it will automatically return the same
operating conditions when the power is restored.
Cooling overload working
In cooling operation, if the temperature of outdoor
heat exchanger is too high, indoor fan speed will
be adjusted to a lower gear automatically and
compressor may be stopped.
Drip proof
In cooling and dehumidification operation, louver
blades can change the position automatically to
prevent from dripping.
SelfClean
After the cooling or dehumidification mode
is turned off, a large amount of water stains
still remains in the evaporator and air duct
of the internal unit. To prevent mildew, mold
and breeding of germs, the air conditioner will
continue to supply air for 3 minutes to dry
residual moisture.