4.1 Special remarks
• 3-minute protection after the compressor
stops
To protect the compressor, it will be off
continuously for at least 3 minutes once it
has stopped.
• 5-minute protection
The compressor must run for at least 5
minutes once it has operated. During these
5 minutes, the compressor will not stop even
that the room temperature reaches the set
temperature point unless you use remote
controller to turn off the unit (all indoor units
can be turned off by the user).
• Cooling operation
The fan of the indoor unit will never stop
running during the cooling operation. It
remains running even if the compressor
stops working.
• Heating operation
Heating capacity depends on external factors
like outdoor unit temperature. Heating
capacity might decrease if outdoor ambient
temperature is too low.
• Anti-freezing function during cooling
When the temperature of the air from the
indoor outlet is too low, the unit will run for
some time under the ventilating mode, to
avoid frost or ice forming in the indoor heat
exchanger.
• Cold air prevention
During several minutes after the heating
mode is started, the fan of the indoor unit will
not run until the heat exchanger of the indoor
unit reaches a certain temperature to prevent
cold draft.
• Defrosting
When the outdoor temperature is too low,
frost or ice may form on the outdoor heat
exchanger, reducing heating performance.
When this happens, the defrosting system
of the air conditioner will operate. At the
same time the fan in the indoor unit stops (or
runs at a very low speed in some cases), to
prevent cold draft. After defrosting is over, the
heating operation and the fan speed resume.
• Blowing out the residual heating air
When air conditioner is stopped during
normal operation, the fan motor would run
at low speed for a while to blow out residual
heating air.
• Auto restart from power break
When the power supply is recovered after
power break, all presets are still effective and
the air conditioner will run according to the
previous setting.
4.2 Trouble shooting
A
Warning:
When the power supply is
recovered after break, all presets
are still effective and the air
conditioner can run according to
the original setting.
If Trouble Still Exists ...
If the trouble still exists even after checking the
following, contact your dealer and inform them of
the following items.
(1) Unit Model Name
(2) Content of Trouble
4 Operation manual