Split type air conditioner / User Manual
9 / 340 EN
shock. All electrical connections
must be made according to the
Electrical connection diagram
located on the panels of the
indoor and outdoor units.
All wiring must be properly
arranged to ensure that the
control board cover can close
properly. If the control board
cover is not closed properly, it
can lead to corrosion and cause
the connection points on the
terminal to heat up, catch fire, or
cause electrical shock.
If connecting power to fixed
wiring, an all-pole disconnection
device which has at least 3mm
clearances in all poles, and
have a leakage current that
may exceed 10mA, the residual
current device (RCD) having
a rated residual operating
current not exceeding 30mA,
and disconnection must be
incorporated in the fixed wiring
in accordance with the wiring
rules.
Take note of fuse
specications
The air conditioner’s circuit
board (PCB) is designed with
a fuse to provide overcurrent
protection. The specifications of
the fuse are printed on the circuit
board, such as:
T3.15AL/250VAC,
T5AL/250VAC, T3.15A/250VAC,
T5A/250VAC, T20A/250VAC,
T30A/250VAC,etc.
C
Note: For the units
using R32 or R290
refrigerant, only the
blast-proof ceramic
fuse can be used.
1 Safety precautions