61 / 135 EN
16
BEHPG
Model name
Indoor unit BEHPG 090 BEHPG 120 BEHPG 180 BEHPG 240
Outdoor unit BEHPG 091 BEHPG 121 BEHPG 181 BEHPG 241
Refrigerant R32 R32 R32 R32
Total Refrigerant Amount (g) 550 550 1100 1450
GWP 675 675 675 675
CO2 equivalent (tonnes) 0.371 0.371 0.743 0.979
Anti-Electric Class I Class I Class I Class I
Climate Class T1 T1 T1 T1
Heating Type Heat Pump Heat Pump Heat Pump Heat Pump
Power Supply Connection Outdoor Outdoor Outdoor Outdoor
Pdesign C (kW) 2.6 3.5 5.3 7.0
Pdesign H (kW)
2.3 (EU Average
Season)
2.5 (EU Average
Season)
4.2(EU Average
Season)
4.9 (EU Average
Season)
SEER/AEER/Weight EER (W/W) 6.2(SEER, EU) 6.1(SEER, EU) 7.0(SEER, EU) 6.4(SEER, EU)
SCOP/ACOP/Weight EER (W/W)
4.0(SCOP, EU
Average)
4.0(SCOP, EU
Average)
4.0(SCOP, EU
Average)
4.0(SCOP, EU
Average)
Energy Level-Cooling A++ (EU) A++ (EU) A++ (EU) A++ (EU)
Energy Level-Heating
A+ (EU Average
Season)
A+ (EU Average
Season)
A+ (EU Average
Season)
A+ (EU Average
Season)
Annual Energy Consumption-
Cooling (kWh)
147 201 265 383
Annual Energy Consumption-
Heating (kWh)
1470 1715
The declared capacity for
calculation of SCOP at reference
design condition (kW)
The back up heating capacity
assumed for calculation of SCOP
at reference design condition
(kW)
Power of Electric Heater (W) / / / /
Cooling Power Input (W)
Heating Power Input (W)
Voltage/Frequency (V/Hz)
1Ph
220V-240V, 50Hz,
1Ph
220V-240V, 50Hz,
1Ph
220V-240V, 50Hz,
1Ph
220V-240V, 50Hz,
826 886
2.2
0.1
2.0
0.5
3.3
0.9
4.0
0.9
799
813
1238
1018
1550
1630
2420
2130