BEKO BEHPG240 handleiding

188 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 16 van 188
16 / 135 EN
Split type air conditioner / User Manual
2.2 Operating temperature
When your air conditioner is used outside of
the following temperature ranges, certain safety
protection features may activate and cause the
unit to disable.
2.3 Inverter split type
COOL mode HEAT mode DRY mode
Room
Temperature
16°C - 32°C
(60°F - 90°F)
0°C - 30°C
(32°F - 86°F)
10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C (32°F - 122°F) -15°C - 24°C
(5°F - 75°F)
for some model
-20°C - 24°C
(-4°F - 75°F)
0°C - 50°C
(32°F - 122°F)
-15°C - 50°C (5°F - 122°F)
(For models with low temp.
cooling systems.)
0°C - 52°C (32°F - 126°F)
(For special tropical models)
0°C - 52°C
(32°F - 126°F)
(For special tropical
models)
For outdoor units with auxiliary electric heater When outside temperature is below 0°C (32°F), we
strongly recommend keeping the unit plugged in
at all time to ensure smooth ongoing performance.
2.4 Fixed-speed type
COOL mode HEAT mode DRY mode
Room
Temperature
16°C-32°C (60°F-90°F)
0°C-30°C
(32°F-86°F)
10°C-32°C (50°F-90°F)
Outdoor
Temperature
18°C-43°C (64°F-109°F)
-7°C-24°C
(19°F-75°F)
11°C-43°C (52°F-109°F)
-7°C-43°C (19°F- 109°F)
(For models with low-temp cooling
systems)
18°C-43°C (64°F-109°F)
18°C-52°C (64°F -126°F)
(For special tropical models)
18°C-52°C (64°F- 126°F)
(For special tropical models)
2 Unit specifications and features

Bekijk gratis de handleiding van BEKO BEHPG240, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkBEKO
ModelBEHPG240
CategorieNiet gecategoriseerd
TaalNederlands
Grootte16432 MB