BEKO BA310AC handleiding

332 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 17 van 332
17 / 224 EN
2 Warnings (for using R290 refrigerant only)
and s sutable for the refrgerant used. Leak detecton equpment
shall be set at a percentage of the LFL of the refrgerant and shall
be calbrated to the refrgerant employed and the approprate
percentage of gas (25 % maxmum) s confrmed. Leak detecton
fluds are sutable for use wth most refrgerants but the use of
detergents contanng chlorne shall be avoded as the chlorne may
react wth the refrgerant and corrode the copper ppe-work. If a
leak s suspected, all naked flames shall be removed/ extngushed.
If a leakage of refrgerant s found whch requres brazng, all of
the refrgerant shall be recovered from the system, or solated (by
means of shut off valves) n a part of the system remote from the
leak. Oxygen free ntrogen (OFN) shall then be purged through the
system both before and durng the brazng process.
12. Removal and evacuaton
When breakng nto the refrgerant crcut to make repars or for any
other purpose conventonal procedures shall be used. However, t
s mportant that best practce s followed snce flammablty s a
consderaton. The followng procedure shall be adhered to:
t
Remove refrgerant;
t
Purge the crcut wth nert gas;
t
Evacuate;
t
Purge agan wth nert gas;
t
Open the crcut by cuttng or brazng.
The refrgerant charge shall be recovered nto the correct recovery
cylnders. The system shall be flushed wth OFN to render the
Local air conditioner