t
That there no lve electrcal components and wrng are exposed
whle chargng, recoverng or purgng the system;
t
That there s contnuty of earth bondng.
7. Repars to sealed components
1) Durng repars to sealed components, all electrcal supples shall be
dsconnected from the equpment beng worked upon pror to any
removal of sealed covers, etc. If t sabsolutely necessary to have an
electrcal supply to equpment durng servcng, then a permanently
operatng form of leak detecton shall be located at the most crtcal
pont to warn of a potentally hazardous stuaton.
2) Partcular attenton shall be pad to the followng to ensure that
by workng on electrcal components, the casng s not altered n
such a way that the level of protecton s affected. Ths shall nclude
damage to cables, excessve number of connectons, termnals not
made to orgnal specfcaton, damage to seals, ncorrect fttng of
glands, etc.
Ensure that apparatus s mounted securely.
Ensure that seals or sealng materals have not degraded such
that they no longer serve the purpose of preventng the ngress of
flammable atmospheres. Replacement parts shall be n accordance
wth the manufacturer’s specfcatons.
C
Note:
The use of slcon sealant may nhbt the effectveness of
some types of leak detecton equpment. Intrnscally safe
components do not have to be solated pror to workng
on them.
2 Warnings (for using R290 refrigerant only)