Baofeng UV-5G Plus handleiding

43 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 25 van 43
25
6.2.1 Scanning modes
The scanner is configurable to one of three ways of operation: Time, carrier or search, each of which is explained in further
details in their respective section below.
Procedure 5.1. Setting scanner mode
1. Press the
key to enter the menu.
2. Enter 2 1 on your numeric keypad to come to scanner mode.
3. Press the
key to select.
4. Use the UP and DOWN keys to select scanning mode.
5. Press the
key to confirm and save.
6. Press the
key to exit the menu.
Time operation
In Time Operation (TO) mode, the scanner stops when it detects a signal, and after a factory preset time out, it resumes
scanning.
Carrier operation
In Carrier Operation (CO) mode, the scanner stops when it detects a signal, and after a factory preset time with no signal it
resumes scanning.
Search operation
In Search Operation (SE) mode, the scanner stops when it detects a signal.
To resume scanning you must press and hold the
key again.
6.2.2 Frequency scanning
This function can scan the frequency.
a. In frequency mode, press
key for more than 2 seconds. The radio will start scanning the frequency according to the
set frequency step.
b. You can change the scanning direction with the / keys.
c. Press
key to stop the scanning.
Note: for Scan mode, see Menu No.21.