Troubleshooting
www.AvantcoRefrigeration.com
8
Problem
Possible Cause
Possible Solution
Compressor
not running.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat set too high. Set thermostat to lower temperature.
Cabinet in defrost cycle. Wait for defrost cycle to finish.
Condensing units run for
long periods of time.
Excessive amount of water product in
cabinet.
Allow adequate time for product to cool down.
Prolonged door opening or door ajar.
Ensure doors are closed when not in use. Avoid
opening the doors for long periods of time.
Dirty condenser coil. Clean the condenser coil.
Evaporator coil iced over.
Unplug unit and allow coil to defrost. Make sure
thermostat is not set too cold. Ensure that door
gasket(s) are sealing properly.
Cabinet temperature is
too warm.
Thermostat set too warm. Set thermostat to lower temperature.
Airflow blocked.
Re-arrange product to allow for proper air flow. Make
sure there is at least 4" of clearance from evaporator.
Excessive amount of warm product
placed in cabinet.
Allow adequate time for product to cool down.
Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.
Dirty condenser coil. Clean the condenser coil.
Prolonged drawer opening or drawer ajar.
Ensure drawers are closed when not in use. Avoid
opening for long periods of time.