www.AvantcoRefrigeration.com
Refrigerated Chef Bases
Chef bases are designed to hold 4" deep food pans. Using the included divider bars, configure each
drawer to best meet specific service needs. Each drawer can hold a combination of full, 1/3, 1/6, or 1/9 pans as
needed.
Defrost System
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime,
the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-o water is drained into the
evaporator pan and evaporated. Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like to
run a manual defrost cycle at any time, please follow the steps below:
Refrigerators:
1. Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
2. Repeat to stop the defrost cycle.