User Manual
Square Bakery Cases
Troubleshooting
Problem
Possible Cause
Possible Solution
Compressor not
running.
Fuse blown or circuit breaker
tripped.
Replace fuse or reset circuit breaker.
Power cord unplugged. Plug in power cord.
Thermostat set too high. Set thermostat to lower temperature.
Cabinet in defrost cycle. Wait for defrost cycle to finish.
Unit is making noise
under the bottom
shelf.
Fan blade is broken. Replace fan blade.
Unit is not cooling.
Unit is turned o. Turn unit on.
Defrost cycle is running. End defrost cycle.
Refrigerant leaking. Contact a licensed service technician.
High cabinet
temperature caused
by weak airflow.
Evaporator coil is frosted over. Run a manual defrost cycle.
Fan is damaged. Replace the fan.
The set point on the controller is too
high.
Set the controller to a lower temperature. The set temperature
is lowest temperature the refrigerator will reach.
Airflow is blocked by product. Rearrange or remove product to allow for complete airflow.
High cabinet
temperature with
normal airflow.
Refrigerant leaking. Contact a licensed service technician.
The set point on the controller is too
high.
Set the controller to a lower temperature. The set temperature
is lowest temperature the refrigerator will reach.
Expansive valve failed. Contact a licensed service technician.
High ambient temperature or
humidity.
The refrigerator is designed to perform in a temperature-
controlled environment up to 75°F and 55% relative humidity.
Cabinet temperature
is fluctuating.
Condenser coil is dirty. Clean the condenser coil.
Unit has improper airflow.
Make sure the unit has at least 6" of clearance on the back
and that the front vents are not obstructed.
Expansion valve blocked or failed. Contact a licensed service technician.
Temperature controller failed. Contact a licensed service technician.
Low refrigerant levels. Contact a service technician to check refrigerant levels.
Condensation is
collecting on the
cabinet and/or floor.
Relative humidity is above 55%.
Move unit to area below relative humidity or lower humidity
level.
Drainage pipe is connected
improperly.
Contact a licensed service technician.