Avantco AU-60R-HC handleiding

9 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 8 van 9
8
User Manual
www.AvantcoRefrigeration.com
Commercial Refrigerators and Freezers
Operation / Maintenance
WARNING: DISCONNECT THE POWER CORD BEFORE CLEANING ANY PARTS OF THE UNIT.
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.
Loading Product
Make sure there is at least 4” of clearance from the evaporator.
Ensure all shelves are sitting level and properly secured before loading products.
Do not store flammable and explosive gas or liquids inside the unit.
Cleaning the Condenser Coil
For ecient operation, keep the condenser surface free of dust, dirt, and lint.
We recommend cleaning the condenser coil at least once per month.
Cleaning the Fan Blades and Motor
If necessary, clean the fan blades and motor with a soft cloth.
If it is necessary to wash the fan blades, cover the fan motor to prevent moisture damage.
Cleaning the Interior of Unit
When cleaning the cabinet interior, use a solvent of warm water and mild soap.
Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the interior finish.
Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of
the door, soak in warm water and soap for thirty (30) minutes, dry with soft cloth, and replace.
Check door gaskets for proper seal after they are replaced.
Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm
water. To remove the pilasters, first remove the shelves and shelf brackets. Then, simply lift the pilaster
up and out.
A dusty condenser may lead to high energy consumption, less cooling eectiveness, and
compressor damage.
CONDENSER COIL CLEANING INSTRUCTIONS:
NOTE: The condenser coil is located at the bottom behind the panel.
1. Disconnect the electrical power from the unit.
2. Remove the front cover and base cover with a screwdriver.
3. Using a soft brush and / or vacuum, remove the dirt, lint, etc. from the finned condenser coil in a
vertical direction.
4. Clean the condenser with a commercial condenser coil cleaner, available from any kitchen equipment
retailer. Ex. Nobel Chemical Tech Line
5. After cleaning, straighten any bent condenser fins with a fin comb.
6. When finished, be sure to reinstall the front cover and base cover.
7. Reconnect the electrical power to the unit.