www.AvantcoRefrigeration.com
Commercial Refrigerators and Freezers
DIGITAL CONTROL UNITS
• Hold “SET” for 1 sec. The display will flash the current minimum temperature.
• Use the arrow buttons to adjust the minimum temperature you want it to run at.
• Press “SET” again to save your settings.
Always remember to calculate the dierential if you change the minimum temperature setting.
The cabinet temperature will fluctuate up to +7 degrees over your set minimum temperature as
the compressor runs and shuts o. Setting the temperature too high will result in unsafe maximum
temperatures.
Controller 2
Figure 2
SET
MUTE
Controller 1
Figure 1
PRG
MUTE
SET
AUX
DEF
Running a Manual Defrost Cycle
This unit is pre-programmed to run automatic defrost cycles at preset intervals. However, if you would like
to run a manual defrost cycle at any time, please follow the steps below:
Controller 1: Press the defrost button (“def” and down arrow) for approximately 5 seconds. Repeat to stop
the defrost cycle.
Controller 2: Press the defrost button (snowflake symbol and down arrow) for approximately 3 seconds.
Repeat to stop the defrost cycle.
Defrost System
Refrigerator coils are kept below the freezing point (32 degrees Fahrenheit). During compressor downtime,
the evaporator fan continues to circulate air through the evaporator coil. This air circulation raises the coil
temperature above the freezing point, melting any accumulated frost. Run-o water is drained into the
evaporator pan and evaporated. Automatic defrost timers automatically initiate at pre-set intervals and for a
pre-determined duration.