• Connect this unit to a grounded power socket with the appropriate voltage (120V/60 Hz).
• The air switch for the power cord should be above 15A.
• Do not connect other electrical appliances in the same socket and do not use multiple sockets.
• Run the cord in a way that nobody can stumble over it or pull on it.
• The cord should never come into contact with sharp edges or hot objects.
• When connecting the unit to gas supply pipe or gas cylinder, a gas shut-o valve has to be fixed
upstream of the unit within the easy reach of the operator.
• Verify the local available gas, and make sure the local gas is the same as that indicated on the
name plate.
• Connect the unit to a suitable gas source with an iron pipe, and make sure there is no sign of gas
leakage. Use a pipe sealant around the joints.
• After connection, use water soap solution to check gas leakage, if there is a sign of leakage; apply the
pipe sealant around the leaking point.
• Consult the local gas supplier about the local gas pressure. If the gas pressure is higher or lower by
10% of the rated gas pressure, a gas release valve has to be fixed upstream of the unit, ensuring the
stability of the gas pressure.
• Minimum clearance from combustible construction:
12" (30 cm) from the sides of the vertical broiler
12" (30 cm) from the back of the vertical broiler
• Minimum clearance from noncombustible construction:
4" (10 cm) from the sides of the vertical broiler
4" (10 cm) from the back of the vertical broiler
• Between the vertical broiler and any open-top flame units: 16" (41 cm)
• Allow space for servicing and operation.
• Install vertical broiler in an area with sucient air supply for gas combustion at vertical broiler burners.
• Do not obstruct the flow of combustion and ventilation air.
• Provide adequate clearance for air openings into the combustion chamber.
• Do not permit fans to blow directly onto vertical broiler.
• Avoid wall-type fans, which create cross-currents within a room.
• Avoid open windows next to sides or back.
NOTE: Before installing the vertical broiler, verify that the type of gas (natural or propane) is in conformity
to the specifications on the vertical broiler data plate, which is located on the back of the unit. Make sure
the vertical broiler is configured for the proper elevation.