User Manual
Heated Holding Cabinets
12
www.AvantcoEquipment.com
Troubleshooting
WARNING
ALWAYS unplug the cabinet from the electrical outlet for safety purposes, minimizing the risk of
electrical shocks.
Problem Possible Cause Solution
Unit not turning on.
Unit unplugged. Ensure the plug is securely set in the outlet.
Improper voltage. Check that the outlet matches the unit's power requirements.
Blown circuit. Check circuit breaker of wall outlet and reset if necessary.
Heat drawer
malfunction.
Remove heat drawer from cabinet.
Remove bottom cover of drawer.
Visually inspect for loose or
disconnected wires, black or burnt
marks on any components, or
loose heating elements.
Loose or disconnected wires: If there
are no burn marks or discoloration on
the wires or surrounding area, connect
or tighten back into place.
Black or burnt marks on any
components: The component and
all wires attached to the damaged
component must be replaced.
Loose heating elements: A loose
heating element's wires will short out on
the metal, causing permanent damage.
Both the element and main power
switch (along with wires on switch) must
be replaced.
Temperature reading
on LED thermometer
not accurate.
Thermometer or
thermometer power
supply failure.
Replace the LED thermometer and its power supply transformer.
Error Code “LL Sensor error. Replace the thermostat.
Error Code “HH”
Temperature of the
cabinet is too high.
Lower the temperature of the cabinet.