1. Upon delivery of the unit, check for shipping damage. Check the packaging and cabinet for shipping
damage after unloading the unit and removing all packaging. Notify freight company immediately of
shipping damage with pictures and a description.
2. After unpacking the cabinet, set on a stable surface and put casters in the lock position where
applicable.
3. Remove all tape and packing material from the outside and inside of the unit.
4. Remove any protective covers on the door and corners of the unit.
NOTE: Use of scrapers (plastic, metal, or other material) to remove the protective film on the door may
cause scratches and impair see-through visibility.
5. After all packaging is removed, plug the cabinet into a dedicated grounded, 120V, 15 or 20 amp
circuit/breaker.
6. Turn the unit on by using the power switch, flip the unit to "heat" mode, and adjust the dial to
maximum setting 9.
7. Allow the unit to run for at least 1 hour to burn in the elements and remove any odors evident from the
manufacturing process.
GFCI TROUBLESHOOTING
A GFCI receptacle protects against “ground faults” whenever an electrical product is plugged into the
GFCI outlet by constantly monitoring the electricity for any loss of current. If the current flowing out of
the receptacle differs by a small amount from that returning, the GFCI quickly switches off power to that
circuit. The GFCI interrupts power extremely fast to minimize the possibility of an electric shock.
• The heater element may absorb some moisture into its casing and insulation during shipment or
during long periods of not being used.
• Plug the cabinet (without water in the stainless steel water pan) into a non-GFCI outlet, set the
temperature to “10,” and let it run for 30-60 minutes to dry out any moisture the element may have
absorbed. After drying the element, plug the cabinet into the GFCI outlet; the cabinet should run
without tripping the GFCI. If the cabinet still trips the GFCI, call RKW warranty provider.