Atlona AT-VGW-250 handleiding
Handleiding
Je bekijkt pagina 78 van 171

Velocity
78
Device Drivers
15. Select AUDIO OUT from the top navigation.
16. Type in all the output ports, separating each with a comma.
18. Select Commands from the top navigation.
19. The basic input commands for the DSP will already be listed. Type in the corresponding commands found within
the device manual.
17. Repeat steps 12 to 14 for VIDEO IN and VIDEO OUT if there are any video ports on the DSP.
NOTE: DSP variables can be used in the commands using the %c for channel and %v for volume level and
mute variable commands.
NOTE: When creating variable command for volume levels and mutes, one must be created for every
channel the DSP has.
To create a volume level variable command, the %c will replace the channel number and the %v will replace the
level.
If the command to change volume level is VOUT2 34, the variable command would be VOUT%c %v. %v will have
the full range of the volume, not just 34, once set up.
To create a mute variable command, the %c will replace the channel number and the %v will replace the mute value.
If the commands to mute or unmute the channel is VMUTE2 ON or VMUTE2 OFF, the variable command will be
VMUTE%c %v. Once set up, the %v will act as ON and OFF.
Bekijk gratis de handleiding van Atlona AT-VGW-250, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Atlona |
| Model | AT-VGW-250 |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 28056 MB |
Caratteristiche Prodotto
| Certificering | CE, FCC |
| Ethernet LAN, data-overdrachtsnelheden | 10,100,1000 Mbit/s |
| Netwerkstandaard | IEEE 802.1x |
| Temperatuur bij opslag | -20 - 60 °C |
| Output current | 3.42 A |