AT-UHD-CAT-2
19
RS-232 Control
The AT-UHD-CAT-2 provides two methods of RS-232 control: Pass-through mode and control mode. The master
RS-232 / IR port, allows the unit to be directly controlled using a control system. In addition two pass-through RS-
232 / IR ports allow sink devices, at the viewing location, to be controlled using a control system.
RS-232 is serial data protocol that allows Data Terminal Equipment (DTE) devices, such a computer or control
system, to communicate with Data Communication Equipment (DCE) devices, such as the AT-UHD-CAT-2 or a
display. Although IP control is available, RS-232 still plays an integral part of many control systems.
The 25-pin D-type connector (DB-25) was dened as the RS-232 standard, but is now commonly implemented in a
nine-pin (DE-9) connector package. Each pin is numbered, as shown below.
Most DTE devices provide a male connector, while DCE devices have a female connector. However, this is not
always the case. If the port type is unknown, then a multimeter can be used to determine whether the port is DTE or
DCE:
Determining the Port Type
DTE Pin Descriptions
DCE Pin Descriptions
Pin Signal Description
1 DCD Data Carrier Detect
2 RxD Receive Data
3 TxD Transmit Data
4 DTR Data Terminal Ready
5 GND Ground (Signal)
6 DSR Data Set Ready
7 RTS Request to Send
8 CTS Clear to Send
9 RI Ring Indicator
Pin Signal Description
1 DCD Data Carrier Detect
2 TxD Transmit Data
3 RxD Receive Data
4 DSR Data Set Ready
5 GND Ground (Signal)
6 DTR Data Terminal Ready
7 CTS Clear to Send
8 RTS Ready to Send
9 RI Ring Indicator
1. Turn on the multimeter and set it to measure DC voltage.
2. Connect the positive and negative leads to pins 3 and 5, respectively.
3. Check the voltage reading:
If the voltage is between -3 V DC and -15 V DC, then the device is DTE.
Otherwise, it is DCE.
Voltage levels between -3 V and -15 V DC represent a logic “1”.
Voltage levels between +3 V and +15 V DC represent a logic “0”.
1 2
Multimeter
3 4 5
6 7 8 9

COM
+
1 2 3 4 5
6 7 8 9
5 4 3 2 1
9 8 7 6
DE-9 (male) DE-9 (female)
1 2 3 4 5
6 7 8 9
5 4 3 2 1
9 8 7 6
Device Operation

Bekijk gratis de handleiding van Atlona AT-UHD-CAT-2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAtlona
ModelAT-UHD-CAT-2
CategorieNiet gecategoriseerd
TaalNederlands
Grootte5847 MB

Caratteristiche Prodotto

Kleur van het productZwart
Gewicht1660 g
Breedte44 mm
Diepte254 mm
Hoogte219.5 mm