Control using TCP Proxy
TCP/IP trac received by an encoder or decoder, on the dened IP:Port socket, are translated to RS-232, allowing
both control of source or display. Control is achieved using a control system, where all control commands are stored.
1. Login to the encoder or decoder and click the SERIAL menu. Under the Serial Port Conguration window
group, for the desired serial port, click the Mode drop-down list and select Serial.
2. Click the SAVE button.
1
3
4
5
6
7
2
3. Under the Serial Conguration 1 window group, click the Port drop-down list and select the desired serial port.
4. Click the Mode drop-down list and select tcpproxy.
5. Click the Interface drop-down list and select the desired Ethernet interface.
6. Enter the listening port in the Port eld.
7. Click the SAVE button.