AP-S15HRIP / AP-S15IP / AP-S158IP
Owner’s Manual
– 11 –
AtlasIED.com
TELEPHONE: (800) 876-3333
SUPPORT@ATLASIED.COM
1601 JACK MCKAY BLVD.
ENNIS, TEXAS 75119 U.S.A.
Unit Features
8. Remote LED Display Port (Included Accessory) - This display control port mates with the included LED display, model AP-LEDIP. This display will
provide a visual reference for the voltage, current, temperature or humidly data within the rack in real time. The AP-LEDIP can also be used to read
the IP address of the unit eliminating the need to use the discovery software.
9. AC Power Programmable Outlets - The AP-S158IP and the AP-S15IP feature eight programable NEMA 5-15P AC switched outlets and the
AP-S15HRIP has five. These switched AC outlets are “live” when the front panel power switch is in the ON position and the outlet is activated via
the WEB interface or by pressing the AC outlet indicator ON/OFF switch (see AC outlet Switches & indicators) If the AC outlet’s corresponding
outlet indicator is illuminated green, the AC outlet is active and AC voltage will be present.
10. AC Outlet ON/OFF Switches and Indicators - Each unit includes AC Outlet ON/OFF switches that also serve as outlet active indicators. Press
the corresponding outlet switch firmly to manually turn a specific AC Outlet ON or OFF. The switch will illuminate green when the corresponding
AC outlet is on. The AC outlets can also be activated by using the interface. Note: The AC Output ON/OFF function can be programmed to be
disabled in the web interface.
Alarm Indicators - The AP-IP power distribution systems feature alarms for the following: Over & Under Voltage, Over Current, Over Temperature
and Over Humidity. All alarm settings are programmed in the web UI. If an alarm is activated, the associated LED will illuminate and the fault
contacts will open.
Factory Reset Switch - The Factory Reset switch is located in the front panel as indicated in the picture below. Insert a small object like a paper
clip into the hole to access the switch. Gently press and hold the switch inward for 3 seconds, then release. The unit’s outlets and display will shut
off and turn back on indicating the Factory Reset was successful. The Factory Reset switch will reset all functions that were previously
programmed and will also reset the unit to accept DHCP IP address. Note: Any custom passwords will be replaced by the last 4 digits of the MAC
address. Before resetting the unit, it is important to write down any special settings that may have been adjusted. Refer to the section Logging
into the Unit for details.
11. Unswitched Outlet (Not Shown in AP-S158IP)
A Unswitched AC outlet is not programable
The AP-S15IP has an unswitched AC outlet that is always live even if the AC mains power switch is in the OFF position. This outlet is protected
by the AC mains breaker, surge protection and by RF filtering.
The AP-S15HRIP has a switched AC outlet that is turned ON/OFF with the AC mains power switch. This outlet is protected by the AC mains
breaker, surge protection and by RF filtering