The key lock function is used to set
‘safe mode’ on the appliance during
operation. It will not be possible to make
any adjustments by pressing the buttons
(for example heat settings). It will only be
possible to switch the appliance off.
The lock function is active if the key lock
button is pressed for at least 2 seconds.
This operation is acknowledged by a
buzzer. After successful operation, the key
lock indicator will flash and the heater will
be locked.
Buzzer
While the hob is in operation, the following
activities will be signalled by the buzzer.
• Normal button activation will be
accompanied with a short sound signal.
• Continuous button operation over a
longer period of time (10 seconds)
will be accompanied with a longer,
intermittent sound signal.
Boost Function
To use this function, select a cooking zone
and set the desired cooking level, then
press the “P” (Boost) button.
The Boost function can only be activated
if it is applicable with the cooking zone
selected. If the Boost Function is active, a
“P” is shown on the corresponding display.
Activating the booster can exceed the
maximum power, in which case the
integrated power management will be
activated.
The necessary power reduction is shown
by the corresponding cooking zone display
blinking. Blinking will be active for 3
seconds to allow for further adaptations of
the settings before power reduction.
Error Codes
If there is an error, an error code will be shown on the
heater displays.
E1 Cooling Fan is disabled. Call an authorised
service agent.
E3 Supply voltage is other than the rated values.
Switch the hob off by pressing ,wait until
“H” disappears for all zones, switch the hob
on by pressing and continue to use. If
the same error is displayed again, call an
authorised service agent.
E4 Supply frequency is different from the rated
values. Switch the hob off by pressing
, wait until “H” disappears from all
zones, switch the hob on by pressing
and continue to use. If the same error is
displayed again, switch the plug for the
appliance off and on. Switch the hob on by
pressing and continue to use. If the same
error is displayed again, call an authorised
service agent.
E5 Internal temperature of the hob is too high,
switch the hob off by pressing and let the
heaters cool down.
E6 Communication error between the touch
control and heater. Call an authorised service
agent.
E7 Coil temperature sensor is disabled. Call an
authorized service agent.
E8 Cooler temperature sensor is disabled. Call
an authorized service agent.
EA Large Coil Saturation Error. Switch the hob
off by pressing on/off button, switch the hob
on by pressing on/off button and continue to
use. If the same error is displayed again, call
an authorised service agent.
EC Supply Voltage Error.Switch the hob off by
pressing on/off button, switch the hob on by
pressing on/off button and continue to use.
If the same error is displayed again, call an
authorised service agent.
C1-C8 Mcroprocessor alert. Switch the hob off by
pressing on/off button, switch the hob on by
pressing on/off button and continue to use.
If the same error is displayed again, call an
authorised service agent.