ATen CN9850 handleiding

189 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 62 van 189
CN9000/CN9600/CN9850/CN9950 User Manual
48
Terminal
The Terminal section allows you to configure the unit using terminal
commands.
Relay Terminal for Remote Reboot
For CN9000/CN9850/CN9950 only, to set the relay terminal to normally
closed (NC) or normally open (NO), or read its status, type the corresponding
command below, and press [Enter]:
set
setset
set
relay
control 0
control 0control 0
control 0
: Set NC-C to a conducting state and NO-C to a
non-conducting state.
set
setset
set
relay
control
control control
control
1: Set NC-C to a non-conducting state and NO-C to
a conducting state.
set
setset
set
relay
control
control control
control
r: Read its current status (0 or 1).
Digital Input
For CN9000/CN9850/CN9950 only, to check the status of the input device
connected, type
getdigitalin
getdigitalingetdigitalin
getdigitalin
and press [Enter].
When the input device’s monitoring parameter exceeds the set threshold, 1 is
returned, otherwise, 0 is returned.

Bekijk gratis de handleiding van ATen CN9850, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkATen
ModelCN9850
CategorieNiet gecategoriseerd
TaalNederlands
Grootte17060 MB