2.1.1.2 Setting Static BMC IP Address through UEFI BIOS
1. Boot to UEFI BIOS SETUP page.
2. Select the Server Mgnt page.
3. Select the BMC Network Configuration page.
4. Navigate to Manual setting IPMI LAN and select the [Yes].
5. Navigate to Configuration address source and select the [Static].
6. Once the Configuration address source is Static, the field of Station
IP Address, Current subnet mask, and Current router IP address
will display 0.0.0.0 and configurable, which indicates users can fill the
new setting value into these fields. After filling the new value into these
fields, press <F10> to save the values and reboot the system to enable
these configured settings values.
Figure 4. Snapshot of Configure BMC Static IP Address