Parameter
Name
Factory preset
Min value
Max value
Signifies
P2024 Outlet temp.
process fi nished
Aut60°
48° 40° 73° For Normal programmes the drying
process ends with cooling.
For Extra programmes the extra
drying time starts, followed by
cooling.
P2025
Extra drying time
Aut60°
30 (min) 10 45 Extra programme drying time after
exhaust temp. has been reached.
P2026 Cooling time
Aut60°
10 (min) 2 20
Time when only the fan is in operation,
without heating elements. Provides
more even drying time.