Location of the Electrical Wiring
ATTENTION:
Do not use extension cables or two-pin adaptors and do not remove the ground terminal of the grounding cable.
ATTENTION:
A qualified electrician must ensure that the poles of the socket are connected correctly.
Verify that the grounding of the socket is correct.
Location of the Water System
The water connected to the water mains must be potable.
Location of the water system must be within the range given below.
Water system of the refrigerator must be connected to the water mains system in the house.
The user must be able to switch it on/off with the valve when necessary.
Objects that might pierce the water hoses or cause them to twist must not be present
where the water line is installed.
Pressure of the water system must be between 25-80 psi (1.7-5.5 Bar).
If the water pressure exceeds 80 psi, install a pressure limiting device or water impact protector to the inlet valve.
Never install the product or operate the appliance if it is possible for the water pressure to exceed 120 psi.
WARNING:
Make sure that there is no water leakage when making the water connections. Otherwise,
there will be water on the floor and the furniture will get damaged.
You will need a hose with a minimum length of 60" (1.5 meters) and a diameter of ¼"
for water connections of the product during installation.
A connector that has a thread with an external diameter of ¼ must be used to connect the hose end to the
product.
Before completing the installation, make sure that water flows and there is no water leakage.