30 L-SeriesPlus User Manual
7 Network Features
7.1 Art-Net and sACN
The L-Series Plus supports Art-Net. Art-Net is a network protocol to control devices.
Here is a brief explanation of some basic terms being used by Art-Net. For more detailed
information, please visit the web site of the Art-Net developers: www.artisticlicence.com.
The device is capable of processing Art-Net for up to ten universes with one sender and three
universes with two senders.
Generals rules of thumb:
Maximum of 4 universes of Art-Net Art-DMX unless you really have to,
All universes of sACN.
Please find more information about sACN in the standard ANSI E1.31. Please observe all
information given there to set up a proper network.
Art-Net IP Address
When setting the IP address manually, please take care the address is in the range 2.0.0.1 to
2.255.255.255 (Network switch off) or 10.0.0.1 to 10.255.255.255 (Network switch on). Any other
range is not according to the Art-Net standard and problems might occur.
Art-Net Net
A group of 16 consecutive Sub-Nets or 256 consecutive Universes is referred to as a net. There are
128 Nets in total.
Sub-Net
A group of 16 consecutive universes is referred to as a sub-net. (Not to be confused with the subnet
mask).
Universe
A single DMX512 frame of 512 channels is referred to as a Universe.
Art-Net Merge Mode
The Art-Net protocol allows multiple nodes or controllers to transmit ArtDmx data to the same
universe. Merging is limited to two sources. If there are additional sources, merging will be de-
activated.
The Merger can act as an LTP or HTP merger (LTP = Latest Takes Precedence, HTP = Highest
Takes Precedence).
Art-Net / sACN Gateway
With enabled Art-Net / saCN gateway the L-Series Plus makes all 512 channels of the used
universe available at its DMX connectors.
The menu Art-Net Settings contains all parameters to set up a L-Series Plus in an Art-Net network.
Please find a detailed description in the section Features of the Device Menu.
The Art-Net / sACN gateway is RDM capable. All RDM compatible devices in a network can be
detected by the integrated RDM controller. RDM management over Art-Net / sACN is supported.
7.2 Network Settings
The Network Settings menu contains various parameters for setting up the L-Series Plus in a
network.
Link shows if the device is connected to a network.
IP displays the IP address of the device when it is connected to a network.
Mode sets the IP mode. In DHCP mode, the IP address, gateway, DNS1 and DNS2 are
automatically assigned to the fixture by the network. You should use this mode if possible.
Art-Net 2.x.x.x.x and Art-Net 10.x.x.x are used to set up the fixture in an Art-Net network.
AutoIP negotiates an IP address automatically when connected to a PC which is set to AutoIP in the
range 169.x.x.x.