55V 11/23
ATTENTION: for maintenance or scrap, please contact authorized service centers. Maintenance by unqualied
person may cause dangers.
APPENDICES
Piping conguration:
PROCEDURE FOR EXTENDING THE PIPING
Note: improper extension of piping is the main cause of refrigerant leaks. Proceed as shown below:
MAINTENANCE NOTES
Connecting pipe diameter Additional refrigerant
Liquid pipe (mm) Gas pipe (mm) (g/m)
Ф6.35 Ф9.52 20
1. Cut the pipe.
Check the length of the pipe based on the
distance between the indoor unit and outdoor
unit.
Cut the required pipe using a pipe cutter.
2. Remove burrs.
Remove burrs with a le, ensuring they do not go
into the pipe.
3. Secure an insulating tube.
Pipe
slanted uneven burred
90°
Pipe cutter
file
pipe
downwards
4. Install a union nut
Remove the union nut on the indoor connecting
pipe and outdoor valve. Install the union nut on
the pipe.
5. Expand the port
Expand the port using a pipe expander:
NB: varies according to diameter
6. Inspection.
Check the quality of the expanded port. If
defective, expand the port again following the
procedure described above.
pipe
union
pipe
pipe
expander
hard
mould
pipe
“A”
smooth surface
equal length
defective expansion
slanted surface
damaged
cracked uneven
thickness
Outdoor diameter (mm)
A (mm)
Max. Min.
6.35(1/4”) 1.3 0.7
9.52 (3/8“) 1.6 1.0
12.7 (1/2“) 1.8 1.0
15.88 (5/8”) 2.4 2.2