Handleiding
Je bekijkt pagina 45 van 59

45V 11/23
Do not repair the air conditioner by yourself as wrong maintenance may cause electric shock or re or explode, please
contact the authorized service center and let the professionals conduct the maintenance, and checking the following
items prior to contacting for maintenance can save your time and money.
TROUBLESHOOTING
WARNING
Phenomenon Causes Troubleshooting
The air conditioner does not work
• There might be power outages.
• Power plug may be loose out from the
socket.
• Power switch fuse may blow.
• The time for timing boot is yet to come.
• Wait until power is restored.
• The plug in the plug tightly.
• Replace the fuse.
• Wait or cancel the timer settings.
The air conditioner does not start after stopping
it
• The air conditioner does not start
immediately due to the protection device
• Wait at least 5 minutes and try again.
The air conditioner stops running after it starts
up for a while
• May have reached the setting temperature.
• May be at a defrosting state.
• Shutdown Timer may be set.
• It is a normal function phenomenon.
• It will automatically restore and run again
after defrosting.
• If you continue to use, please turn it on
again.
The wind blows out, but the cooling/heating
effect is not good
• Excessive accumulation of dust on lter,
blocking at air inlet and outlet, and the
excessively small angle of the louver blades
all will affect the cooling and heating effect.
• Poor cooling and heating effect caused by
doors and windows opening, and unclosed
exhaust fan.
• Mode setting is incorrect, and the
temperature and wind speed settings are
not appropriate.
• Please clean the lter, remove the obstacles
at the air inlet and outlet and regulate the
angle of the louver blades.
• Please close the doors, windows, the
exhaust fan, etc.
• Please re-select the mode, and set the
appropriate temperature and wind speed.
The indoor unit blows out odor
• The air conditioner itself does not have
undesirable odor. If there is odor, it may
be due to accumulation of the odor in the
environment.
• Clean the air lter or activate the cleaning
function.
There is sound of running water during the
running of air conditioner
• When the air conditioner is started up or
stopped, or the compressor is started up
or stopped during the running, sometimes
the “hissing” sound of running water can
be heard.
• This is the sound of the ow of the
refrigerant, not a malfunction.
A slight “click” soundis heard at the of start-up
or shut-down
• Due to temperature changes, panel and
other parts will swell, causing the sound of
friction.
• This is normal, not a fault.
The indoor unit makes abnormal sound
• The sound of fan or compressor relay
switched on or off. When the defrosting is
started or stop running, it will create sound.
• Too much dust accumulation on the air lter
of the indoor unit may result in uctuation
of the sound.
• Too much air noise when “Strong wind” is
turned on.
• That is due to the refrigerant ows to reverse
direction. They are not malfunctions.
• Clean the air lters in time.
• This is normal, if feeling uncomfortable,
please deactivate the “strong wind”
function.
There are water drops over the surface of the
indoor unit
• When ambient humidity is high, water
drops will be accumulated around the air
outlet or the panel, etc.
• Prolonged cooling run in open space
produces water drops.
• Too small opening angle of the louver
blades may also result in water drops at
the air inlet.
• This is a normal physics phenomenon.
• Close the doors and windows.
• Increase the angle of the louver blades.
During the cooling operation, the indoor unit
outlet sometimes will blow out mist.
• When the indoor temperature and humidity
are high, it happens sometimes.
• This is because the indoor air is cooled
rapidly. After it runs for some time, the
indoor temperature and humidity will be
reduced and the mist will disappear.
Bekijk gratis de handleiding van Argoclima Newage Plus, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
Merk | Argoclima |
Model | Newage Plus |
Categorie | Airco |
Taal | Nederlands |
Grootte | 7714 MB |