34V 12/24
1. POWER BUTTON
Press this button to switch the unit on or off.
2. MODE BUTTON
When the unit is on, press this button to choose the desired mode among: fan, dehumidifying and cooling.
The corresponding LEDs will light up according to your selection
3. SPEED BUTTON
In the cooling mode, press this button to adjust the ventilation speed to low (Low) or high (High).
In dehumidifying mode, it’s not possible to select the ventilation speed, therefore fan will forcefully choose the low
fan speed.
4. DOWN BUTTON
Press this button to adjust the temperature and set the time.
5. UP BUTTON
Press this button to adjust the temperature and set the time.
6. TIMER / WIFI BUTTON
Timer function:
1. When the air conditioner is off, press “TIMER” to set when to switch the unit on. Press “UP” or “DOWN“ to
set the time, and press “TIMER” again to conrm.
2. When the air conditioner is on, press “TIMER” to set when to switch the unit off. Press “UP” or “DOWN“ to
set the time, and press “TIMER” again to conrm.
To deactivate the Timer function, press the UP and DOWN buttons repeatedly until the display shows “00”
Pressing the POWER button deactivates the timer function. The timer time selection interval is 0-24 hours.
Wi Function:
Long press this button to start the network conguration or disconnect the WIFI.
7. SLEEP BUTTON
In cooling mode, press the button to activate the Sleep function, then the unit will operate silently and save energy.
After 1 hour of operation the temperature increases by 1 °C, after the second hour the temperature increases
again by 1 °C.
Note: the Sleep function is not available in dehumidication or ventilation mode but only in cooling.
8. CHILD LOCK BUTTON
Press this key to turn the control panel lock function on or off.
TEMPERATURE AND ERROR DISPLAY
The display will show the temperature set in cooling mode, while if the unit is operating in dehumidication, the
display will show the room temperature.
Refer to the table below if the following errors appear on the display:
Problem Cause Solution
E1 Room temperature sensor failure. Contact a service centre.
E2
Failure of temperature sensor on the
evaporator.
Contact a service centre.
E0
Communication faults between main
PCB and display PCB.
Contact a service centre.
Ft Alarm of full water tank
Connect the PVC pipe to the condensate
drain hole