Arecont Vision MicroDome Duo AV10655DN-28 handleiding

32 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 19 van 32
Microdome Duo® Installation Manual
Page | 19 support@arecontvision.com
+1.818.937.0700 | 877.CAMERA.8 | www.arecontvision.com | avsales@arecontvision.com
OUTPUT Relay Control and Function
The camera has an output for activating an external device. The camera supports both transient and
continuous relay operation. You can operate the relay during an active connection using the API command set.
Typical applications include turning on lights or activating doors and locks.
IN+ IN- GNDOUT+ OUT-
0-120VDC
100mA
(max)
+
-
Relay wiring with power source to the camera
Camera output can be turned on|off with the following command:
http://camera_ip/set?auxout=(“on”|“off”)
The following table shows the output control and electrical characteristics:
Output Control
Terminals
External Status
Camera Status
Max Voltage
Max Current
OUT+ & OUT-
OPEN
OFF
120V
-
CLOSED
ON
-
100mA

Bekijk gratis de handleiding van Arecont Vision MicroDome Duo AV10655DN-28, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.