Arecont Vision MegaView
®
2 Installation Manual
Page | 7 support@arecontvision.com
Optional: Connecting Digital I/O:
9. To use digital I/O, connect digital I/O with
pigtail cable connector as shown in Image
8.
NOTE 1: MegaView
®
2 only supports digital
input but no digital output.
NOTE 2: Table 1 shows electrical
characteristics
Electrical
Characteristics:
Min
Max
Input voltage (V)
(measured between
+ and terminals)
ON
2.9
6.3
OFF
0
1.3
OFF
-
0.1
Table 1
NOTE 3: The digital input is electrically isolated
from the rest of the camera’s electrical circuitry
via general-purpose photo couplers. The input
is additionally protected with a serial 250 Ohm
resistor, and a debouncing circuit. Duration of
any input signal should be at least 5 ms to
comply with the requirements of the debouncing
circuit.
NOTE 4: Table 2 shows cable color for digital
input
Green
Digital IN +
Black
Digital IN -
Table 2