Contera Bullet | Installation Manual
Camera Power Up
CAUTION!
This product should be installed by a qualified service technician in accordance with the National
Electrical Code (NEC 800 CEC Section 60) or applicable local code. Wiring methods shall be in accordance
with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction.
Wiring should be UL Listed and/or Recognized wire suitable for the application.
CAUTION!
Make the connections inside a watertight compartment. Isolate unused power wires individually.
After connections are made, ensure that the watertight compartment is tightly closed and cables and
conduits are properly sealed to prevent ingress of water.
CAUTION!
This product is intended to be supplied by a Listed Power Adapter or DC power source, rated
(1) 24 VAC , 0.416 A, 50/60Hz ;(2) 12-48 VDC, 0.83-0.2 A ;(3) 48 VDC, 0.27 A (for PoE), Tma = 50 °C, and
the altitude of operation = 2000m. If need further assistance with purchasing the power source, please
contact to ARECONT VISION COSTAR LLC for further information.”
1. Connect the camera to a PoE port on 100Mbps network PoE switch using an Ethernet cable.
2. If the camera is powered by an outside power supply, 12~48VDC or 24VAC (red and black wires),
connect the power cable.
3. Connect the PoE switch to your computer’s network port using an Ethernet cable.
LED
Status
Description
Green Quick Flashing Link has been established
Slow Flashing Normal operation