TROUBLESHOOTING
Before calling for service, review this list. It may save your time and expense. This list includes common
occurrences that are not the result of defective workman-ship or materials in this appliance.
Problem Solution
Air conditioner
does not start.
Wall plug disconnected. Push plug rmly into wall outlet.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type
or reset circuit breaker.
Plug Current Device Tripped. Press the RESET button.
Power is OFF. Turn power ON.
Air from unit does
not feel cold
enough.
Room temperature below 62°F (17°C). Cooling may not occur until room temperature rises
above 62°F (17°C).
Temperature sensing behind air lter element touching cold coil. Keep it from the cold coil.
Set to a Lower temperature.
Compressor stopped when changing modes. Wait for 3 minutes after set to the COOL mode.
Air conditioner cooling,
but room is too warm -
ice forming on cooling coil
behind decorative front.
Outdoor temperature below 64°F (18°C). To defrost the coil, set FAN ONLY mode.
Air lter may be dirty. Clean lter. Refer to Care and Cleaning section.
To defrost, set to FAN ONLY mode.
Thermostat set too cold for night-time cooling. To defrost the coil, set to FAN ONLY mode.
Then, set temperature to a Higher setting.
Dirty air lter- air restricted. Clean air lter. Refer to Care and Cleaning section.
Temperature is set too High, set temperature to a Lower setting.
Air directional louvers positioned improperly. Position louvers for better air distribution.
Front of units is blocked by drapes, blinds, furniture, etc.
This restricts air distribution. Clear blockage in front of unit.
An open doors, windows,or register may allow cold air to escape.
Close any doors, winows, or registers.
The room may be too warm. Allow additional time to remove “Stored heat” from walls, ceiling,
oor and furniture.
Air conditioner
turns on and o rapidly
Dirty air lter- air restricted. Clean air lter.
Outside temperature extremely hot.
Set FAN speed to a Higher setting to bring air past cooling coils more frequently.
Noise when unit is cooling
Air movement sound. This is normal . If too loud, set to a slower FAN setting.
Window vibration - poor installation. Refer to installation instructions or check with installer.
Water dripping INSIDE
when unit is cooling.
Improper installation. Tilt air conditioner slightly to the outside to allow water drainage. Refer
to installation instructions - check with installer.
Water dripping OUTSIDE
when unit is cooling.
Unit removing large quantity of moisture from humid room.
This is normal during excessively humid days.
Remote Sensing
Deactivating Prematurely
(Only remote models)
Remote control not located within range. Place remote control within 20 feet and pointed in
the general direction of the air conditioner unit.
Remote control signal obstructed. Remove obstruction.
Room too cold Set temperature too low. Increase set temperature.
The design and specications are subject to change without prior notice for product improvement. Any updates to
the manual will be uploaded to the Arctic Wind website (www.arcticwindac.com), please check for the current version.

Bekijk gratis de handleiding van ARCTIC WIND 3AWH8000A, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkARCTIC WIND
Model3AWH8000A
CategorieAirco
TaalNederlands
Grootte4452 MB