OPERATION INSTRUCTIONS
(Continued)
To operate on DRY mode
In this mode, the air conditioner will generally
operate in the form of a dehumidier. Since the
conditioned space is a closed or sealed area,
some degree of cooling will occur.
In Dry Mode, the fan speed is automatically
set to Low and cannot be adjusted.
9. TIMER: AUTO START/STOP FEATURE
Press Timer button, the TIMER ON or TIMER OFF
indicator light illuminates. It indicates the Auto
Start or Auto Stop program is initiated. For some
units, keep pressing the Timer button will cancel
the timer settings.
Press or hold the UP or DOWN button to change the
Auto time by 0.5 hour increments, up to 10 hours,
then at 1
hour increments up to 24 hours. The
control will count down the time remaining until start.
The selected time will register in 5 seconds,
and the system will automatically revert back to
display the previous temperature setting or room
temperature when the unit is on. (When the unit
is o, there is no display.)
Turning the unit ON or OFF at any time or
adjusting the timer setting to 0.0 will cancel the
Auto Start/Stop timed program.
10. DISPLAY
Shows the set temperature in ”°F" or ”°C" and the
Auto-timer settings. While on FAN only mode, it
shows the room temperature.
If the room temperature has more than two digits
and cannot be displayed on the screen, it will
display "HI" or "LO".
Error codes:
AS - Room temperature sensor error
ES -Evaporator temperature sensor error
HS -Electric heating sensor error;
CS -Condenser temperature sensor error;
OS -Outside temperature sensor error;
E7 -Unit malfunction.
NOTE: When error occurs, unplug the unit and
plug it back in. If error repeats, call for service.
CAUTION If the unit breaks o unexpectedly
due to the power cut, it will restart with the
previous function setting automatically when the
power resumes.
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating
procedure, here are more features in your control
that you should become familiar with.
The Cool circuit has an automatic 3 minutes
time delayed start if the unit is turned o and
on quickly. This prevents overheating of the
compressor and possible circuit breaker tripping.
The fan will continue to run during this time.
The control is capable of displaying temperature
in degrees Fahrenheit or degrees Celsius. To
convert from one to the other, press and hold
the Up and Down (or +/- symbols) buttons at the
same time for 3 seconds.