26
AQUASURE HARMONY SERIES
SYSTEM TROUBLESHOOTING
Use your phone to scan the QR code below or visit https://aquasureusa.com/support for most up
to date system troubleshoot. You can also contact our support team at support@aquasureusa.com.
Flow Rate @ 50 psi (3.5 bar) Valve Alone:
Continuous 15 psi (1 bar) Drop: 20 gpm (76 lpm)
Peak 25 psi (1.7 bar) Drop: 26 gpm (98 lpm)
Max Backwash 25 psi (1.7bar) Drop: 7 gpm (26 lpm)
CV 1 psi (0.07 bar) Drop: 5.0
Regeneration/Backwash:
Downow/Upow: Downow Cycles: 5
Adjustable Cycles: All
Time Available: Up to 999 minutes per cycle
Meter:
Accuracy Range:
Turbine Paddle 0.25 - 15 gpm
(0.95 - 57 lpm) ± 5%
Capacity Range: 1 - 9,999,999 gal
Valve Specifications:
Inlet/Outlet: 1" or 3/4", NPT
Mounting Base: 2-1/2" 8 NPSM
Distributor Pilot: 1.05" OD
Drain Line: 1/2" Quick Connect Elbow
Brine Line: 3/8" Quick Connect
Height: 7" (178 mm)
Weight
(Valve Gross): 4.84 lb (2.1 kg)
Additional Information:
Electrical Rating: Input: 120V AC 60Hz, Output: 24 V DC
Max. VA 3 VA
Water Pressure:
Hydrostatic: 300 psi (21 bar)
Working: 20 - 125 psi (1.4 bar - 8.6 bar)
Temperature: 34 - 110 °F (1 - 43 °C)