21
B - For F21 it may be tricky and risky to take off by the hands only. You can help yourself with a plastic stick or plastic head tweezers.
Put this on one edge and lift up slightly the front group to release the o-ring. Take the front group and pull it out with the hands.
POSSIBLE BUT NOT RECOMMENDED: For F18-F21-F135 it is possible to use vacuum system with plastic suction head or a suction grip to
pull out the front group. Be aware that you must use those systems correctly to prevent from any damage on the front element. Angenieux will
not be responsible of any damage caused using this method. Clean properly the front element and the suction head before putting it in place.