16
NSTALLATION
WIRING DIAGRAM
Important! Heating elements operate at 230V.
Recommended
connection lead
1 230 V single phase connection with
a neutral lead, terminals 1-2-3 are
bridged, neutral lead to terminal 4,
and the protective conductor to
1N~ H05VV-F3G4
3X 4 mm
2
2 400/230V two phase connection
with a neutral lead, terminals
2-3 are bridged, neutral lead to
terminal 4, and the protective
conductor to
2N~ H05VV-F4G2,5
4X2,5mm
2
3 For a 400/230 V three phase
connection with a neutral lead
connected to terminal 4, and the
protective conductor to
3N~ H05VV-F5G1,5
5X1,5mm
2
L1=R, L2=S, L3=T, N=neutral lead connection, =protective lead terminal
Important! For each connection
the protective conductor must
be connected to the terminal
marked
1
2
3
4
PE
L1
N
1
2
3
4
L1
L2
PE
N
1
2
3
4
L1
L2
PE
N
L3
OPERATION
Before using the appliance for the rst time
● Thoroughly clean your ceramic hob rst. The ceramic hob should be treated with the
same care as a glass surface.
● Switch on the ventilation in the room or open a window, as the appliance could emit
an unpleasant smell during rst use.
● Operate the appliance while observing all safety guidelines.