The following instructions are intended for a qualied professional installer. These instructions
are intended to provide the most professional installation and maintenance of the appliance.
Requirements for the place of installation
Kitchen should be dry, airy and well ventilated according to the applicable technical
regulations.
The room should be equipped with a ventilation system to extract the combustion gases
outside the room. The ventilation system must include a ventilation grille or a hood. Hoods
must be installed in accordance with the accompanying operating instructions.
The room should also allow air supply which is necessary for the correct combustion of
gas. The air supply should be not less than 2 m³/h per 1 kW of the burners power. Natural
airow from the outside may be provided or through a duct with a cross-section of at least
100 cm², or indirectly from the adjacent rooms that have ventilation ducts leading outside.
l Before you install the appliance, make sure that the local distribution conditions
(gas type and pressure) and the appliance conguration is appropriate.
l Conguration details are given on the appliance nameplate.
l This appliance is not connected to ues. The appliance must be installed and con-
nected in accordance with the current regulations. In particular, consideration must
be given to the applicable requirements for ventilation.
INSTALLING
Min. 420 mmMin. 420 mm
Min. 650 mm
Min. 150 mm