Surface burners applied do not require adjust-
ment of primary air. A correct ame has dis-
tinct internal cones of blue and green colour.
A short, humming ame or long, yellow and
smoking one, without clearly outlined cones,
shows improper quality of gas in the house-
hold piping or a damaged or soiled burner.
In order to check a ame, heat a burner for
around 10 minutes with a full ame, and next
turn the valve knob to the economical ame
position. The ame should not go out or jump
onto the nozzles.
INSTALLATION
Caution!
Adapting the appliance to a di󰀨erent
type of gas than that indicated by the
manufacturer of the cooker on the
data plate, or purchasing a cooker for
a di󰀨erent type of gas than supplied to
the house, is exclusively the responsi-
bility of the user and the tter.
Exchange of a burner noz-
zle unscrew the nozzle
with special socket span-
ner No 7 and replace with
a new one according to a
type of gas (see tables).
In cookers with a safety device, a knob with
a surface burner safety valve is used, g.
Knobs should be adjusted with the burner
switched on and set to the economical ame
position, using an adjustment screwdriver of
the 2.5 mm size.
Caution!
After adjustment is completed, place
a label indicating the type of gas to
which the cooker is now adapted.
Adjustment
valve

Bekijk gratis de handleiding van Amica A5KG8.2, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.