5
RATING PLATE The information on the rating plate denes the model, serial
number, gas type (natural or liquid propane), operating pressures and burner BTU
ratings. Keep this information for future reference. It is essential for proper identication
of the unit when requesting additional information or factory support.
Appliances must be connected only to the type of gas identied on the rating plate.
GAS CONNECTIONThe single deck oven requires one gas connection; the double deck oven requires two gas connections. The
gas inlet line size of this appliance is 3/4" NPT. For proper operation, the gas service supply line must be the same size or greater than the
inlet line size of the appliance.
MANUAL SHUT-OFF VALVEA gas pressure regulator and a contractor-supplied shut-o valve must be plumbed in the gas
service line ahead of the appliance – in a physical location where it can be reached quickly in the event of an emergency.
A
DCE
F
G
C
B B
C
G
F
ECD
A
H
NATURAL GAS
LP GAS
A
. Gas pressure regulator
B. 90º Street elbow
C. Adapter (must be 3/4" male pipe thread)
D. Flexible connector
E. Manual gas shut-off valve
F. 3/4" gas supply
G. Use pipe-joint compound
A. Gas pressure regulator
B. 90º Street elbow
C. Adapter (must be 3/4" male pipe thread)
D. Flexible connector
E. Manual gas shut-off valve
F. 3/4" gas supply
G. Use pipe-joint compound
H. Step down regulator
The gas pressure regulator must be installed in the gas line – failure to install a pressure regulator will void the equipment warranty. The
regulators supplied with ranges have 3/4" NPT connections; the regulator is adjusted at the factory for 5" W.C. (water column) manifold
gas pressure (natural gas) or 10" W.C. manifold gas pressure for propane gas operation.
Before connecting the regulator, check the incoming line pressure – as these regulators can only withstand a maximum inlet pressure of
14" W.C. (1/2 PSI); exceeding this pressure will damage them. Visually double check any installer-supplied intake pipes and/or blow them
out using compressed air to clear any dirt or debris, threading chips, or other foreign matter – before installing a service line. Those
particles will clog gas orices when gas pressure is applied. Compounds used on threaded joints of this appliance piping must be resistant
to the action of NG and LP gas and provide a gas tight seal to prevent leaks. If the gas supply line pressure is greater than this amount, a
step-down regulator will be required. A gas ow direction arrow is cast into the body of the regulator to minimize installation error – it
should point downstream to the appliance. The blue air vent cap on the top of the regulator is part of the regulator and should not be
removed.
Any adjustment to the regulator must be made
only by qualied and licensed service personnel
with the proper calibrated test equipment. Gas
connections should be performed by a qualied
licensed contractor.
INSTALLATION
!
WARNING
Rating Plate
Clearances – The appliance must be
kept free and clear from all combustible
materials. This unit is designed and certied
for the following installation only:
CLEARANCE FROM MINIMUM COMBUSTIBLE AND NON-COMBUSTIBLE CONSTRUCTION
COMBUSTIBLE NON-COMBUSTIBLE
Back 0" 0"
Side 6" 0"
0"
6"
INTENDED FOR OTHER THAN HOUSEHOLD USE.
FOR INSTALLATION UNDER VENTIL ATION HOOD ONLY,
AND NONCOMBUSTIBLE LOCATION ONLY.
ANSI Z83.11-2016 / CSA 1.8-2016.