CAUTION! THE USE OF PROTECTIVE
GLOVES AND SAFETY GOGGLES IS
STRONGLY RECOMMENDED WHILE
PERFORMING THE IP PRESSURE TEST!
AVOID PLACING YOUR FACE, EYES, HANDS,
ETC IN PROXIMITY TO THE LENS OF THE
FIXTURE WHILE PERFORMING THE TEST!
IP PRESSURE TESTING PARAMETERS
Low Pressure
Limit
High Pressure
Limit
Steady/Hold
Time
1.65 psi
(11.4 KPa)
1.70 psi
(11.7 KPa)
3 sec
IP TEST PARAMETERS
Following any repair or maintenance procedure that requires disassembly of the fixture, use ADJ’s
Hydro IP Tester to confirm the IP integrity of the fixture. The air valve is located on the same side as
the Power Out and DMX Out ports, as shown in the diagram below. Please contact ADJ Service for
information regarding the ADJ Hydro IP Tester, or visit the product information page online at: https://
www.adj.com/hydro-ip-tester
DE-HUMIDIFICATION: IP65 xtures operating in high-humidity environments may experience residual
fogging or condensation. Such fogging will not affect the xture, and can be removed using the following
procedure: position the unit with the air valve pointing upwards, then open the air valve and run the
unit for 1-2 hours after reaching operating temperature. Then, while the xture is still hot, re-install the
air valve and allow the unit to cool down. Please note: this procedure should be performed in a dry,
climate-controlled environment. Avoid additional fogging by drying the xture completely before placing
into a road case.
Air
Valve
36