DAISY CHAIN POWER LINKING
These units have the capability to be daisy chained together via the power in/out ports. The maxi-
mum number of units that can be linked together in this manner is as follows:
• 4 units maximum when running on 120V power.
• 8 units maximum when running on 230V power.
DO NOT EXCEED THE NUMBER OF UNITS LISTED ABOVE.
DO NOT MIX MAKE AND MODEL TYPES WHEN DAISY CHAINING! All units that are connected in
this manner must be of the same make and model type.
CLEANING AND MAINTENANCE
DISCONNECT POWER BEFORE PERFORMING ANY MAINTENANCE!
CLEANING
Frequent cleaning is recommended to ensure proper function, optimized light output, and an extend-
ed life. The frequency of cleaning depends on the environment in which the xture operates: damp,
smoky, or particularly dirty environments can cause greater accumulation of dirt on the xture’s op-
tics. Clean the external lens surface periodically with a soft cloth to avoid dirt/debris accumulation.
NEVER use alcohol, solvents, or ammonia-based cleaners.
MAINTENANCE
Regular inspections are recommended to ensure proper function and extended life. There are no
user serviceable parts inside this xture. Please refer all other service issues to an authorized ADJ
service technician. Should you need any spare parts, please order genuine parts from your local ADJ
dealer.
Please refer to the following points during routine inspections:
• A detailed electrical check by an approved electrical engineer every three months, to make sure
the circuit contacts are in good condition and prevent overheating.
• Be sure all screws and fasteners are securely tightened at all times. Loose screws may fall out
during normal operation, resulting in damage or injury as larger parts could fall.
• Check for any deformations on the housing, color lenses, rigging hardware, and rigging points
(ceiling, suspension, trussing). Deformations in the housing could allow for dust or liquids to enter
into the xture. Damaged rigging points or unsecured rigging could cause xture to fall and seri-
ously injure a person(s).
• Electric power supply cables must not show any damage, material fatigue, or sediments.
NEVER remove the ground prong from the power cable.