Alto-Shaam HFT2-300 handleiding

28 pagina's
PDF beschikbaar

Handleiding

Je bekijkt pagina 12 van 28
MN-29506 (REV. 6) 11/15 • HFT2/HFT2SYS SERIES MERCHANDISERS 10
ELECTRICAL CONNECTION
INSTALLATION
The appliance must be installed by a qualified
service technician. The oven must be properly
grounded in accordance with the National
Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle
ONLY, positioning the unit so that the plug is
easily accessible in case of an emergency. Arcing
will occur when connecting or disconnecting the
unit unless all controls are in the offposition.
Proper receptacle or outlet configuration or
permanent wiring for this unit must be installed
by a licensed electrician in accordance with
applicable local electrical codes.
REGARDING INTERNATIONAL
STANDARD UNITS:
If the unit is not equipped with flexible cord with
plug, an all-pole country approved disconnection
device which has a contact separation of at least
3mm in all poles must be incorporated in the fixed
wiring for disconnection. When using a cord
without a plug, the green/yellow conductor shall
be connected to the terminal which is marked with
the ground symbol. If a plug is used, the socket
outlet must be easily accessible. If the power cord
needs replacement, use a similar one obtained
from the distributor.
WARNING
To prevent SERIOUS INJURY,
DEATH, or PROPERTY DAMAGE:
All electrical connections must be
made by a qualified and trained
service technician in accordance
with applicable electrical codes.
This appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence
of local codes, with the current
edition of the National Electrical
Code ANSI/NFPA No. 70. In Canada,
all electrical connections are to be
made in accordance with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.
WARNING
To prevent SERIOUS INJURY, DEATH
or PROPERTY DAMAGE:
All electrical connections must be
made by a qualified and trained
service technician in accordance with
applicable electrical codes.
DANGER
Ensure power source matches
voltage identified on appliance rating
tag. The rating tag provides essential
technical information required for any
appliance installation, maintenance
or repairs. Do not remove, damage or
modify the rating tag.
Wire diagrams are included in the literature
package supplied with the unit.
For CE approved units:
To prevent an electrical
shock hazard between the appliance and other
appliances or metal parts in close vicinity,
an equalization-bonding stud is provided. An
equalization bonding lead must be connected to
this stud and the other appliances/metal parts
to provide sufficient protection against potential
difference. The terminal is marked with
the following symbol.
HFT2-300 ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS
k
W PLUG CONFIGURATION
208 240 1 60 13.0 – 15.0 2.7 3.6
NEMA
6-20P
20A - 250V
PLUG
230 1 50 14.7 3.4
CEE 7/7,
220-230V PLUG
HFT2-400 ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS
k
W PLUG CONFIGURATION
208 240 1 60 13.8 – 15.6 2.9 – 3.8
CORD, NO PLUG
230 1 50 15.3 3.5
CORD, NO PLUG
HFT2-500 ELECTRICAL
VOLTAGE PHASE CYCLE/HZ AMPS
k
W PLUG CONFIGURATION
208 240 1 60 15.2 – 17.6 3.2 – 4.2
CORD, NO PLUG
230 1 50 17.2 4.0
CORD, NO PLUG

Bekijk gratis de handleiding van Alto-Shaam HFT2-300, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.

Productinformatie

MerkAlto-Shaam
ModelHFT2-300
CategorieNiet gecategoriseerd
TaalNederlands
Grootte4604 MB