INSTALLATION
Delux e C ont rol Cook & H o l d ▪ O p er a tor’s Ma n u al ▪ M N-46708 ▪ R ev 1 ▪ 1/ 2 1
28
How to Install the Oven
Before you begin Make sure you have an appropriate lifting device, and enough personnel, to
safely move and position the weight of the oven.
Requirements
▪ The oven must be installed on a level surface.
▪ The oven must not be installed in any area where it may be affected by steam,
grease, dripping water, high temperature, or any other severely adverse
conditions.
Voltages
Continued on next page
V Ph Hz AWG A Breaker* kW Plug***
300-TH
230V 120
230
1
1
60
50/60
14
14
6.7
3.2
15
16
0.8
0.7
NEMA 5-15P
15A-125V
CEE 7/7,
BS-1363, CH2-16P
500-TH
120V
208-240V**
230V
120
208
240
230
1
1
1
1
60
60
60
50/60
10
10
10
10
16
11
13
12
20
15 UL | 20 CSA
15 UL | 20 CSA
16
1.9
2.3
3.0
2.8
NEMA 5-20P
20A-125V
No cord, no plug
CEE 7/7,
BS-1363, CH-16P
750-TH
120V
208-240V**
230V
120
208
240
230
230
1
1
1
1
1
60
60
60
50/60
50/60
10
10
10
10
10
14
15
17
17
20
20 UL | 30 CSA
20 UL | 30 CSA
32
16
1.7
3.1
4.2
3.8
2.6^
NEMA 5-20P
20A-125V
No cord, no plug
No cord, no plug
CEE 7/7,
BS-1363, CH-16P,
CH2-16P
750-SK
120V**
208-240V**
230V
120
208
240
230
230
1
1
1
1
1
60
60
60
50/60
50/60
10
10
10
10
10
17
17
19
18
20
20 UL | 30 CSA
20 UL | 30 CSA
32
16
2.0
3.5
4.5
4.2
2.9^
No cord, no plug
No cord, no plug
No cord, no plug
No cord, no plug
CEE 7/7,
BS-1363, CH-16P,
CH2-16P,
*Electrical connections must meet all applicable federal, state, and local codes.
**Dedicated circuit required.
***Additional cord and plug configurations available from factory.
^ Reduced wattage configuration.