Alfatron ALF-12X-SDIC, ALF-20X-SDIC
22
5.
Serial port communication and control
The camera could be controlled through RS232/RS485 interface; RS232C serial parameter are as follows:
Baud rate: 2400/4800/9600/115200 bits / sec; Start bit: 1; data bits: 8; Stop bit: 1; Parity: None.
5.1 VISCA Protocol Return Command
Ack/Completion Message
Command packet
Note
ACK z0 41 FF Returned when the command is accepted.
Completion z0 51 FF Returned when the command has been executed.
z = camera address + 8
Error Messages
Command packet
Note
Syntax Error z0 60 02 FF
Returned when the command format is different or when a
command with illegal command parameters is accepted
Command Not
Executable
z0 61 41 FF
Returned when a command cannot be executed due to
current conditions. For example, when commands
controlling the focus manually are received during auto
focus.