Alcon AquaComfort Plus handleiding
Handleiding
Je bekijkt pagina 17 van 48

17
as the trial lenses. Record rotation compensation as part of the nal Rx.
D. Initial Visual Evaluation
The visual result is evaluated by rst performing a spherical over-
refraction and then measuring visual acuity. If visual acuity is
acceptable, the determination of lens power required after the
over-refraction will be uncomplicated. In this case, the axis in
accepted notation will be the difference between the absolute value
determined and 180 degrees.
Example:
Diagnostic Lens: -2.00 -0.75 x 180
Over-refraction: -0.50 sphere
Final Power to Order: -2.50 -0.75 x ...*
*Determination of nal cylinder axis to order will be made
after compensation for lens orientation.
If the spherical over-refraction does not yield acceptable vision
proceed to perform a spherocylindrical over-refraction. For
the resultant lens power to order from this over-refraction call
Professional Consultation in the U.S.A. at 1-800-241-7468 or visit
www.virtualconsultant.alcon.com.
FITTING GUIDELINES
(FOCUS
®
DAILIES
®
Progressives Contact Lenses)
The FOCUS
®
DAILIES
®
Progressives (nellcon A) lens is a progressive
aspheric simultaneous vision soft contact lens. The lens design
incorporates a constant near power prole into each lens across the
full range of distance powers. This simplies the tting procedure by
eliminating add powers as a separate variable. For each lens, the near
and intermediate powers are concentrated primarily in the central portion
of the optical zone while the surrounding portion is weighted towards
distance. The continuous changes in power across the surface of the
lens allow patients requiring a reading addition of up to +3.00D to see
clearly at far, intermediate and near distances.
1. PATIENT SELECTION
The eye care professional should weigh several factors when considering
patient selection for a FOCUS
®
DAILIES
®
Progressives (nellcon A) soft
contact lens tting. When tting a lens intended to correct for presbyopia,
it is especially important to evaluate the particular visual needs, objectives,
lifestyle and expectations of the individual patient. Prospective candidates
may include current contact lens wearers, former wearers, and persons with
no previous wear history. For former wearers it is important to determine the
cause for discontinuation. Good success has been achieved with FOCUS
®
DAILIES
®
Progressives lenses in all three wearing groups.
There are two general categories of candidates based on anticipated usage:
those who seek to wear their lenses as their principal means of vision
correction, and those who wish to integrate the use of their contact lenses
Bekijk gratis de handleiding van Alcon AquaComfort Plus, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.
Productinformatie
| Merk | Alcon |
| Model | AquaComfort Plus |
| Categorie | Niet gecategoriseerd |
| Taal | Nederlands |
| Grootte | 4631 MB |
Caratteristiche Prodotto
| Materiaal | Nelfilcon A |
| Aantal per verpakking | 90 stuk(s) |
| Type product | Dagelijks |
| Ultraviolet ( UV) bescherming | Nee |
| Lens diameter | 14 mm |