7. TROUBLESHOOTING
Symptom Inspection Solution
The unit
is not
operating.
Check the power connec-
tion in securely.
Insert the power cord securely into the
wall Outlet.
Check if the water level
indicator lights up?
Empty the drain pan by remove the
rubber plug.
Check the room tempera-
ture.
The range of operating temperature is
5-35ºC.
The unit
works with
reduced
capacity
Check the air lter for dirt Clean the air lter as necessary.
Check if the air duct is
blocked.
To clear the obstacle.
Check if the room door or
window is open.
Keep the door and windows closed.
Check if the desired
operating mode is selected
and the temperature is
properly set.
Set the mode and temperature at
proper set-point according the manual.
(refer to STEP 4)
The exhaust hose is
detached.
Make sure the exhaust hose is securely
attached.
Water
Leakage
Overow while moving the
unit.
Empty the water tank before transport.
Check if the drain hose is
kinked or bends.
Straighten the hose to avoid a trap
existing.
Excessive Noise Check if the unit is securely
positioned.
Place the unit on horizontal and rm
ground.
Check if any loose, vibrating
parts.
Secure and tight the parts.
Noise sounds like water
owing.
Noise comes from owing refrigerant.
This is normal.
Error
Codes
E0 Communication faults
between main PCB and
display PCB
Check the wire harness of the display
PCB for damage.
E1
Ambient temperature
sensor failure
Check connection or replace it. To clean
or replace the temperature sensor
E2
Coil temperature sensor
failures.
Check connection or replace it. To clean
or replace the temperature sensor.
FT
Condensate water high
level alarm.
Empty the drain pan by removal the
rubber plug.