HOW TO INSTALL & PRECAUTIONS
HOW TO INSTALL &
PRECAUTIONS
● SELECTION OF THE INSTALLATION PLACE
● HOW TO CONNECT PIPES
•As the air conditioner should be connected to the tap water tube, its installation near the hydrant is good.
Install it on the even and stable place.
1. Connect the nipple at the water in-taking hole and the water discharge hole of the backside
of the air conditioner. At this time, wind the Teflon tape at the thread part and fasten it the main body.
2. Unfasten the nut and ring at the nipple and connect it to the hose, and insert the hose into the nipple
and fasten it by using the nut.
(When connecting the hose, make the cut surface of the hose even.)
3. Connect the water in-taking hole to the tap water tube (or a pressuring pump), and the water discharge hole
to the drain hole.
(Pay attention for not changing the water in-taking hole with the discharging hole.)
4. Connect the discharging hose with the condensed water discharge hole and to the draining hole.
5. Once the pipe connection is finished, open the valve of water supply line so that water is supplied.
At this time, as water is discharged only when the air-conditioner is operated, check whether water is
discharged from the drain hole.
HOSE
HOSE
The Sink
T-type tube
Tap water nozzle
Tap water tube
WATER OUT
WATER IN
DRAIN