ECONOMY MODE
TROUBLE SHOOTING
ECONOMY MODE /
TROUBLE SHOOTING
Model
Evap. Fan Cond. Fan
Economy mode
(Push the button
for 3 sec.)
Etc.
Economy Normal Economy Normal
HSC-12P
Stop after
30 sec.
Run - -
Fan integral
type
HSC-14P/18P/24P
Stop after
30 sec.
Run - -
Fan integral
type
HWC-19P
Stop after
30 sec.
Run Stop Run
(High)
HSC-36P/60P/70P
Stop after
1 min.
Run
Stop after
1 min.
Run
AHSC-14P/18P
Stop after
30 sec.
Run - -
Fan integral
type
AHSC-42/60
Stop after
30 sec.
Run Stop Run
AHSC-140P
Stop after
1 min.
Run
Stop after
1 min.
Run
Symptom Check Points Measures to be Taken
- Is the power plug pulled out? - Insert the plug.
- Is the operation stopped? - Press ON/ OFF switch, and confirm
the lamp condition.
- Is the fuse cut? - Change the fuse of electric panel.
- Is the circuit breaker fallen? - After confirming the load capacity, raise
the circuit breaker of the distribution panel.
- Is the surrounding temperature too high? - Use it at the place of 113℉ and lower.
(Higher than 113℉)
- Is the voltage too low? - Request an electricity construction
- company for the available rated voltage
- Is the filter clogged with dust? - Clean the filter (Washing with water is OK.)
- Although the filter is clean, is the heat- - Clean the heat-exchanger.
exchanger clogged with much dust?
- Is there any obstacle in the in-taking part? - Remove the obstacle. (Farther than 8inch.)
- Is the set-temperature correctly set? - For cooling, adjust the set temperature
lower than the ambient temperature.
- Is the water supply cut? - Confirm the water supply valve is opened.
- Right after the operation stops, is the unit - Confirm that after 3 minutes, the compressor
started to operate instantly? is normally operated and the cold air is being
discharged.
The operation
is not done.
The cooling is
not well done.
When white vapor
is generated
during operation.
- Is the unit being used where humidity is high?
- If the humidity is high, much air is discharged,
and white vapor may be emitted.
When dew is
formed at the
discharging
hole.
- Is the room temperature too high?
- It is a phenomenon that the moisture in
the air is changed into dew, and this is
not abnormal.