9.4 MST Port Setting
Instructions:
1. Click the “Spanning Tree > MST Port Setting” in the navigation bar, check the port to
be modified from the list of all ports of the device, “Edit” to enter the detailed
configuration interface as follows:
Interface data are as follows.
Configuration
Items
Description
MSTI
Select the instance for configuration through the drop-down box in
the upper left.
Port
Select the port to be configured by users
Path Cost
Enter the path cost value of the interface Use IEEE 802.1t Standard
with the value ranging from 0 to 200,000,000
Priority
Select the port priority with smaller value representing higher
priority.
Interface priority affects the role of the interface on the specified
MSTI. On different MSTI, users can configure the priorities for a
Bekijk gratis de handleiding van Airlive L3-XGF28, stel vragen en lees de antwoorden op veelvoorkomende problemen, of gebruik onze assistent om sneller informatie in de handleiding te vinden of uitleg te krijgen over specifieke functies.